Printronix MVP Series Printer User Manual


 
Interfaces 85
Dataproducts Interface
The optional Dataproducts interface transfers parallel data at a rate of up to
400,000 characters per second. It requires an I/O cable assembly with
Winchestercompatible connector (Printronix P/N 110628001) as shown in
Figure 83 or an Amphenolcompatible connector (Printronix P/N 110638
001) connected to the properly terminated Parallel Controller PCBA at P4.
Configuration Option 66 must be set to 66.1
Figure 83. Dataproducts Connector
Figure 84 illustrates the Dataproducts interface timing sequence. The printer
signals status to the host computer by putting a high on the DATA
REQUEST line along with READY and ONLINE. The host computer places
a data byte on the input lines. After the data has stabilized for at least 50 ns,
the computer issues DATA STROBE to latch the data byte into the receiver
latches. DATA STROBE also causes DATA REQUEST to go low, and must
go low again itself at least 50 ns before the data byte is withdrawn by the
host computer. At least 1 us later, the printer will return the DATA
REQUEST line to a high state and again be ready to accept data.
Figure 84. Dataproducts Interface Timing Sequence