4–Non-Interactive Commands
Command Summary
SN0054614-00 K 4-21
# scli -kl (<hba instance> | <hba wwpn>)
To do a loopback test with customized parameters, type:
# scli -kl (<hba instance> | <hba wwpn>) [(<param name> |
<param alias>) <param value>]
Where:
Sections “DataPattern (DP)” on page 4-21 through “LoopbackType (LT)” on
page 4-24 describe how to change the default parameters for both of these tests.
“Run a Loopback Test” on page 4-24 contains command line examples and test
results for a loopback test. “Run a Read/Write Buffer Test” on page 4-28 contains
command line examples and test results for a read/write buffer test.
DataPattern (DP)
For the loopback test, the data pattern is either:
DP <param value>
DataPattern <param value>
hba instance = Adapter number (use -g command to find)
hba wwpn = World wide port name of the adapter
-ex or -exclude = World wide port name of the target device to be
excluded from the read/write test
param name = One of the following:
DataPattern (see “DataPattern (DP)” on page 4-21)
DataSize (see “DataSize (DS)” on page 4-23)
TestCount (see “TestCount (TC)” on page 4-23)
TestIncrement (see “TestIncrement (TI)” on
page 4-23)
OnError (see “OnError (OE)” on page 4-24)
LoopbackType (see “LoopbackType (LT)” on
page 4-24)
param alias = One of the following:
DP (see “DataPattern (DP)” on page 4-21)
DS (see “DataSize (DS)” on page 4-23)
TC (see “TestCount (TC)” on page 4-23)
TI (see “TestIncrement (TI)” on page 4-23)
OE (see “OnError (OE)” on page 4-24)
LT (see “LoopbackType (LT)” on page 4-24)
param value = Value for selected parameter