Q-Logic FC0E Network Card User Manual


 
4–Non-Interactive Commands
Command Summary
SN0054614-00 K 4-25
Table 4-10 lists the operating system driver versions that do not require a
loopback connector.
.
To do a loopback test using the current parameters, type:
# scli --kl (<hba instance> | <hba wwpn>)
To do a loopback test with custom parameters, type:
# scli --kl (<hba instance> | <hba wwpn>) [(<param name> |
<param alias>) <param value>]
Section “-kl (Loopback Test)” on page 4-20 describes the parameters and their
default values.
The following examples do 500 loopback tests with a test increment of 10, a data
pattern of FFh, and a data size of 8 bytes. The test stops if an error occurs.
# scli -kl <hba wwpn> DP FF DS 8 TC 500 TI 10 OE 1
NOTE:
The loopback test is disabled if you are using the drivers from the OS
installation and not functional on the QLE8042 adapter.
NOTE:
Run an echo test instead of a loopback test under the following conditions:
You have a QLA23xx, QLA24xx, QLE23xx, or QLE24xx adapter that is
connected to the fabric through a point-to-point connection (F_Port).
The adapter is connected to a switch.
Your operating system has one of the driver versions listed in
Table 4-10.
Table 4-10. Driver Versions Not Requiring a Loopback Connector
Operating System
Driver Version
a
a
All subsequent versions also apply.
Windows XP, Windows 2000, or Windows Server 2003 with SCSI
miniport driver
9.0.0.12
Windows Server 2003 with STORport miniport driver 9.0.0.12
Solaris SPARC 4.12
Table Notes