Reading & Changing Operating Parameters at Runtime
Joystick Min, Max and Center Values
Address: ^12 - Joystick Center 1 MS
^13 - Joystick Center 1 LS
^14 - Joystick Center 2 MS
^15 - Joystick Center 2 LS
^16 - Joystick Min 1 MS
^17 - Joystick Min 1 LS
^18 - Joystick Min 2 MS
^19 - Joystick Min 2 LS
^1A - Joystick Max 1 MS
^1B - Joystick Max 1 LS
^1C - Joystick Max 2 MS
^1D - Joystick Max 2 LS
Effective: Instantly
These parameters are the Gains values that are loaded after the controller is reset or pow-
ered on. These Gains apply to both channels. Gains can be changed at Runtime, and values
can be different for each channel using separate commands (see page 121).
Gains values are integer number from 0 to 63. This number is divided by 8 internal so that
each increment equals 0.125.
Reading & Changing Operating Parameters at Runtime
It is possible to change several of the controllers operating modes, on-the-fly during nor-
mal operation. Unlike the Configuration Parameters that are stored in Flash (see above),
the Operating Parameters are stored in RAM and can be changed indefinitely. After reset,
the Operating Parameters are loaded with the values stored in the Configuration Parameter
flash. They are then changed using RS232 commands.
Use the command following commands to Read/Change the Operating Modes
Syntax: ^mm Read Parameters at location mm
^mm DD Write Parameters DD in location DD
mm and DD are Hexadecimal values.
Bit Definition See pages
7:0 8 bit value. Two registers used to form one 16 bit
number for each Joystick parameter.
Default values (in decimal):
Min = 4400
Center = 1600
Max = 3200
page 90