Closed Loop Position Mode
66 AX500 Motor Controller User’s Manual Version 1.9b. June 1, 2007
Roborun will detect the new hardware revision and display Rev B on the screen.
Analog inputs 3 and 4 have different characteristics than inputs 1 and 2, and so require a
lower resistance potentiometer in order to guarantee accuracy.
Important Notice
This wiring is also the one to use when the controller is in Analog mode but switched to
RS232 after reset using the method discussed in “Entering RS232 from R/C or Analog
mode” on page 105
Analog Feedback on Single Channel Controllers
On Single Channel controllers (SC Version - not to be confused with Dual Channel control-
lers of which only one channel is used for position control - See “Single Channel Opera-
tion” on page 177.), the controller accepts one command and uses one input for feedback.
Feedback Wiring in RC or RS232 Mode on Single Channel Controllers
When the controller is configured for RS232 or RC command, the wiring of the feedback
must be done as shown in the figure below.
10 Ana2
14 +5V
5 Ground
Feedback 1
Command 1
Command 2
Feedback 2
11 Ana1
8 Ana4*
2k 2k 2k - 10k 2k - 10k
12 Ana3*
FIGURE 37. Pot wiring for Analog Command and Analog Feedback
Feedback
2k - 10k
10 Ana2
14 +5V
5 Ground
11 Ana1
8 Ana4*
12 Ana3*
FIGURE 38. Pot wiring on Single Channel controllers (SCversion) and Analog Command