929 Iin in Pll Mode Iin Pll - - - R R 0 0 = input voltage and current are not in not PLL
1 = PLL
930 Test Mode Test Mode - - - R/W R/W 0 Range: 0 – 65535
931 Test No Test No - - - R/W R/W 0 Range: 0 – 65535
932 Fault and Warning Simulation
Number
FltWrn SimNo - - - R R/W 0 Range: -32768 – 32767
933 Current Limit Counter CLMT Cntr - - - R R 0
934 uC’s Port 2 Hardware Logic P2 HWLogic - - - R R 0
935 uC’s Port 9 Hardware Logic P3 HWLogic - - - R R 0
936 Generate RTC Clock Out Gen RTC Clock - - - R/W R/W 0
937 Service Port Startup Security
Level (non-volatile)
Srv StrtupSlvl W W W R/W R/W 3 0 = User
1 = Administrator
2 = Distributor
3 = QC & Service
4 = Engineering
938 SNMP Port Startup Security
Level (Non-volatile)
Prot StrtupSlvl - - - R/W R/W 0 0 = User
1 = Administrator
2 = Distributor
3 = QC & Service
4 = Engineering
939 Display CAN Port Startup
Security Level (Non-volatile)
Can StrtupSlvl - - - R/W R/W 3 0 = User
1 = Administrator
2 = Distributor
3 = QC & Service
4 = Engineering
940 uC’s Port 9 Hardware Logic P9 - - - R R 0
941 Triangular Wave Tri - - - R/W R/W 0 Enable/Disable Triangular Waveform. Range: 0 – 65535
942 Clear All Counters ClrAllCnt - - - R/W R/W 0 1 = clear all counters (Ex. Commands 701, 702, 703,
707, 708, 709, 711, 713, 715, 719, 721, 725 are cleared)
0 = do nothing
943 Measure RTC Frequency Mea RTC Freq - - - R R