Toshiba B-850 Printer User Manual


 
2. SYSTEM MODE EO13-33003
2.3 Printer Parameter Fine Adjustment
2-35
• Example of X Coordinate Fine Adjustment
When setting –50.0 mm
Compared with “+0.0mm” position, the print
position is shifted to the left.
When setting +0.0 mm
When setting +50.0 mm
Compared with “+0.0mm” position, the print
position is shifted to the right.
NOTES:
1. The X coordinate fine adjustment is performed to fine adjust the print position in horizontal direction (left or
right).
2. Adjust the X coordinate within the effective print range. After the value reaches the coordinate 0, the value
remains unchanged even if the subsequent fine adjustment is performed in the negative direction.
3. This adjustment cannot be used in the Self Test mode or Test print.
4. The fine adjustment value equals to the sum of the fine adjustment values set by the PC command and this
parameter. The maximum X coordinate fine adjustment value is +
99.9 mm. When the value reached the
maximum, the value remains unchanged even if the subsequent fine adjustment is performed.
ABC
Feed Direction
ABC
ABC
50.0mm
50.0mm
Top Down Printing
X
Y
Bottom First Printing
X
Y