Toshiba B-850 Printer User Manual


 
2. SYSTEM MODE EO13-33003
2.6 RAM Clear
2-53
2.6 RAM Clear
Outline of RAM Clear
In the RAM Clear mode, clearing the Maintenance Counter and initializing the Parameters are possible.
After replacing the print head, ribbon motor, or platen, perform a maintenance clear.
The RAM Clear menu contains the following:
How to Enter RAM Clear Mode
Turn on the printer while pressing the [FEED] and [PAUSE] keys at the same time. Hold both keys until the
“<1>DIAG. Vx.x” Message appears.
Press the [FEED] key 5 times. The printer is at the start of the RAM Clear menu.
2.6.1 RAM Clear Menu Selection
When “<6>RAM CLEAR” appears, press the [PAUSE] key.
Choose a RAM Clear menu among “No RAM Clear”, “Maintenance Counter Clear”, or “Parameter Clear”.
NOTES: 1. To exit the RAM clear menu selection, press the [FEED] and [RESTART] keys at the same. The
display returns to “<6>RAM CLEAR”.
2. Even after performing a RAM clear, the following items are still stored: Label distance covered,
Sensor adjustment value, IP address, Socket port number, Language for the LCD message, data in
the flash memory.
<1>DIAG. Vx.x
<6>RAM CLEAR
NO RAM CLEAR
MAINTE.CNT CLEAR
PARAMETER CLEAR
<6>RAM CLEAR
No RAM Clear
[PAUSE]
[FEED]
[FEED]
[FEED]
Maintenance Counter Clear
Parameter Clear
[RESTART]
[RESTART]
[RESTART]
NO RAM CLEAR
MAINTE.CNT CLEAR
[RESTART]
[FEED]
PARAMETER CLEAR
RAM Clear is not performed.
Clears the Maintenance Counter.
Clears the Parameter.