2. SYSTEM MODE EO13-33003
2.6 RAM Clear
2-55
Initial values after clearing the parameters (PARAMETER CLEAR)
Item Initial Value
Feed amount fine adjustment (PC), (KEY) 0 mm
Cut position (or stop position of the strip issue) fine adjustment
(PC), (KEY)
0 mm
Reverse feed amount fine adjustment (PC), (KEY) 0 mm
Print tone fine adjustment (Thermal transfer), (PC), (KEY) 0
Print tone fine adjustment (Thermal direct), (PC), (KEY) 0
Ribbon take-up motor driving voltage fine adjustment (PC), (KEY) 0
Ribbon feed motor driving voltage fine adjustment (PC), (KEY) 0
Threshold manual fine adjustment for the lower black mark sensor 1.0V
Threshold manual fine adjustment for the feed gap sensor 1.4V
X coordinate fine adjustment (KEY) 0 mm
Character code and zero font code PC-850, “0” (without slash)
Baud rate 9600 bps
Data length 8 bits
Stop bit 1 bit
Parity None
QP type XON/XOFF + READY/BUSY (DTR) protocol:
(XON output when the power is on,
XOFF output when the power is off)
Flow control code
QQ type READY/BUSY (DTR) protocol
LCD message language English
Forward wait ON
Control code AUTO
Feed key function FEED
Kanji code type TYPE1
Euro code B0H
Auto print head check OFF
ACK/BUSY timing TYPE 1
Web printer function ON
Input prime (Reset operation when INIT signal is ON.) OFF: Available
Expansion I/O mode Standard mode
QP type OFF Plug & Play
QQ type ON
Print processing at the label end/ribbon error detection
The printer stops an issue operation.
Maxi code specification selection TYPE1 (Compatible with the current version)
Automatic calibration OFF
LAN enable/disable LAN: Enabled, SNMP: Enabled
Status response ON
Label pitch 76.2 mm
Effective print length 74.2 mm
Effective print width
216.8 mm
Printing mode Thermal transfer
Sensor type Feed gap sensor
Print speed 4”/sec.
Issue mode Batch print
PC save automatic calling ON
Basic interpreter OFF: Unavailable
Basic interpreter trace OFF: Unavailable
DHCP function OFF: Unavailable
RTC low battery check OFF
RTC data renewal timing BATCH
NOTE: The initial values of Data length, Parity, Control code, LCD message language are different according
to the destination code.