Toshiba B-850 Printer User Manual


 
3. ON LINE MODE EO13-33003
3.7 Real Time Clock (RTC) Setting
3-12
NOTES:
1. Be sure to load the battery and set the low battery check function to ON whenever the real time clock is used.
If the battery is not loaded or the battery voltage is low, the real time clock data is erased at the power off time.
2. When the low battery check function is set to ON, the printer stops at the power on time due to a “LOW
BATTERY” error if the battery voltage is 1.9V or less. As a restart is invalidated in this case, hold down the
[RESTART] key to cause the printer to enter <1>RESET mode, access the Real Time Clock setting mode, and
set the low battery function to OFF.
3. The factory setting for the low battery check function is OFF.
4. To enable the real time clock function, set the low battery check to ON.
5. When the low battery check is set to OFF, the RTC function is available even in a low battery state. However,
the setting and check of the real time clock is required whenever the power is turned on.
6. When the RTC data renewal timing is set to “PAGE”, the printer stops between labels ignoring the on-the-fly
issue even when an Issue command is sent to print more than one label.
(Continued from the previous page)
Set the second with the [FEED] or [RESTART] key. Press
the [PAUSE] key to fix the Second. Then, the Low Batter
y
Check selection screen is displayed.
Pressing the [PAUSE] key enables choosing whether to
activate the low battery check function or not. Set the
function to ON or OFF with the [FEED] or [RESTART] key.
ON: Low battery check function is activated.
OFF: Low battery check function is not activated. (Default)
Press the [PAUSE] key to fix the setting. Then, the RTC
Data Renewal Timing setting screen is displayed.
Pressing the [PAUSE] key enables choosing the RTC data
renewal timing.
Choose PAGE or BATCH with the [FEED] or [RESTART]
key.
PAGE: A real time can be printed on each media. However, the
printer needs to stop the motion before printing each
media to read the real time clock data.
BATCH: Batch print is possible. However, the same time is
printed on the all media issued in a batch because the real
time clock data is read only for the first media.
Press the [PAUSE] key to fix the setting. Then, the curren
t
date is displayed.
[PAUSE]
TIME S 10/30/00
[PAUSE]
[FEED]
[RESTART]
Second
LOW BATT. CHECK
[PAUSE]
LOW BATT. OFF
[PAUSE]
[FEED]
[RESTART]
RENEWAL
[PAUSE]
RENEWAL BATCH
[PAUSE]
[FEED]
[RESTART]
DATE 06/03/01
Press the [FEED] and [RESTART]
keys at the same time to return to
“<8>RTC SET” display.
<8>RTC SET