Toshiba H3 Power Supply User Manual


 
TOSHIBA
8 - 1
*Item 9 is available only when Item 8 Adjustment Range option 1 or 2 is selected.
GROUP:FUNDAMENTAL PARAMETERS #1
PARAMETER
DESCRIPTION
LIQUID CRYSTAL DISPLAY ADJUSTMENT
RANGE
ITEM
NO.
PAGE
NO.
DISPLAY
RESOLUTION
FACTORY
SETTING
MAXIMUM OUTPUT 1 Maximum frequency 30 - 400 Hz 0.01/0.1 Hz 80 Hz 9-3
FREQUENCY
BASE FREQUENCY #1 2 Base frequency #1 25 - 400 Hz 0.01/0.1 Hz 60 Hz 9-3
BASE FREQUENCY 3 Base frequency voltage selection 0: Input voltage level - 1 9-3
VOLTAGE SELECT 1: Automatic setting
2: Stationary setting
MAXIMUM OUTPUT 4 Maximum voltage #1 for 230V 0 - 255V 1V 230V 9-3
VOLTAGE #1 Maximum voltage #1 for 460V 0 - 510V 1V 460V 9-3
REVERSE OPERATION 5 Reverse operation disable selection 0: Reverse allowed - 0 9-3
DISABLE SELECT 1: Reverse not
allowed
UPPER LIMIT 6 Upper limit frequency 0.0 Hz - Maximum 0.01/0.1 Hz 80.0 9-3
FREQUENCY Output Frequency
LOWER LIMIT 7 Lower limit frequency 0.0 Hz - Upper 0.01/0.1 Hz 0.0 9-3
FREQUENCY Limit Frequency
VOLTS PER HERTZ 8 V/F pattern 1: Constant torque * - 1 9-3
PATTERN 2: Variable torque *
3: Automatic torque
boost
4: Automatic torque
boost with
automatic energy
savings feature
5: Vector control
6: Vector control with
automatic energy
savings feature
VOLTAGE BOOST #1 9 * 30 HP and less 0 - 30% 0.1% 3% 9-4
40 HP and greater 1%
ACCELERATION TIME #1 10 60 HP and less 0.1-6000/0.01-600.0 0.1s/0.01s 10 sec 9-4
75 HP and greater 60 sec
DECELERATION TIME #1 11 60 HP and less 0.1-6000/0.01-600.0 0.1s/0.01s 10 sec 9-4
75 HP and greater 60 sec
ACC/DEC PATTERN #1 12 Acc/Dec pattern #1 0: Linear - 0 9-4
SELECTION 1: Self-adjusting
2: S-Pattern
3: Overspeed Pattern
ACCEL/DECEL PATTERN 13 Acc/Dec pattern adjustment 0 - 50 1% 25 9-5
ADJUST LOW amounts (low)
ACCEL/DECEL PATTERN 14 Acc/Dec pattern adjustment 0 - 50 1% 25 9-5
ADJUST HIGH amounts (high)
SECTION 8: Programming Charts