Toshiba H3 Power Supply User Manual


 
TOSHIBA
8 - 8
GROUP:FREQUENCY SETTING PARAMETERS
PARAMETER
DESCRIPTION
LIQUID CRYSTAL DISPLAY ADJUSTMENT
RANGE
ITEM
NO.
PAGE
NO.
DISPLAY
RESOLUTION
FACTORY
SETTING
Table continued on next page
*Items 84 - 87 are available only when Item 83 Adjustment Range option 1 is selected.
**Items 89 - 92 are available only when Item 88 Adjustment Range option 1 is selected.
***Items 94 - 97 are available only when Item 93 Adjustment Range option 1 is selected.
FREQUENCY PRIORITY 80 Assign priority to frequency 1:RR terminal - 1 9-13
SELECTION #1 reference sources 2:IV terminal
3:RX terminal
4:PG input
5:Binary input or MOP
FREQUENCY PRIORITY 81 Assign second priority 1:RR terminal 2 9-13
SELECTION #2 frequency reference source 2:IV terminal
3:RX terminal
4:PG input
5:Binary input or MOP
ANALOG INPUT FILTER 82 Analog input filter 0 - 3 - 0 9-14
RR TERMINAL STANDARD 83 RR input selection 0: Standard - 0 9-14
OR ADJUSTABLE 1: Adjustable * 5-1
RR REFERENCE SETTING 84* RR reference point #1 0 - 100% 1% 0 9-14
POINT #1 of terminal max (10V)
RR REF POINT #1 85* Output frequency desired 0 - Max. Out. Freq. 0.1/0.01 Hz 0.0 9-14
FREQUENCY with input entered in Item 84
RR REFERENCE SETTING 86* RR reference point #2 0 - 100% 1% 100 9-14
POINT #2 of terminal max (10V)
RR REF POINT #2 87* Output frequency desired 0 - Max.Out. Freq. 0.1/0.01 Hz 80.0 9-14
FREQUENCY with input entered in Item 86
IV TERMINAL STANDARD 88 IV input selection 0: Standard - 0 9-14
OR ADJUSTABLE 1: Adjustable ** 5-1
IV REFERENCE SETTING 89** IV reference point #1 0 - 100% 1% 20 9-14
POINT #1 of terminal maximum
IV REF POINT #1 90** Output frequency desired 0 - Max. Out. Freq. 0.1/0.01 Hz 0.0 9-14
FREQUENCY with input entered inItem 89
IV REFERENCE SETTING 91** IV reference point #2 0 - 100% 1% 100 9-14
POINT #2 of terminal maximum
IV REF POINT #2 92** Output frequency desired 0 - Max. Out. Freq. 0.1/0.01 Hz 80.0 9-14
FREQUENCY with input entered in Item 91
RX TERMINAL STANDARD 93 RX input selection 0: Standard - 0 9-14
OR ADJUSTABLE 1: Adjustable *** 5-1
RX REFERENCE SETTING 94*** RX reference point #1 -100 - 100% 1% 0 9-14
POINT #1 of terminal maximum
RX REF POINT #1 95*** Output Hz desired with input -Max. Out. Freq. to 0.1/0.01 Hz 0.0 9-14
FREQUENCY entered in Item 94 Max. Out. Freq.
RX REFERENCE SETTING 96*** RX reference point #2 -100 - 100% 1% 100 9-14
POINT #2 of terminal maximum
RX REF POINT #2 97*** Output Hz desired with input -Max. Out. Freq. to 0.1/0.01 Hz 80.0 9-14
FREQUENCY entered in Item 96 Max. Out. Freq.
Specifications
Precautions
Wiring
JumpersPanelKeypadParametersProgrammingServiceDimensionsIndex Inspection