Blade ICE G8124 Personal Computer User Manual


 
BLADEOS 6.5.2 Application Guide
BMD00220, October 2010 Chapter 12: Virtual NICs 163
5. Add ports, trunks, and virtual pipes to their vNIC groups.
Once VLAN 1000 and 1774 are configured for vNIC groups, they will not be available for
configuration in the regular VLAN menus (/cfg/l2/vlan).
Note – vNICs are not supported simultaneously on the same switch ports as VMready, or on the
same switch as DCBX or FCoE.
6. Save the configuration.
RS G8124(config)# vnic vnicgroup 1 (Select vNIC group)
RS G8124(vnic group config)# vlan 1000 (Specify the VLAN)
RS G8124(vnic group config)# member 1.1 (Add vNIC pipes to the group)
RS G8124(vnic group config)# member 2.1
RS G8124(vnic group config)# port 4
RS G8124(vnic group config)# port 10
RS G8124(vnic group config)# failover (Enable vNIC failover for the group)
RS G8124(vnic group config)# enable (Enable the vNIC group)
RS G8124(vnic group config)# exit
RS G8124(config)# vnic vnicgroup 2
RS G8124(vnic group config)# vlan 1774
RS G8124(vnic group config)# member 1.2
RS G8124(vnic group config)# member 2.2
RS G8124(vnic group config)# member 3.2
vNIC 3.2 is not enabled.
Confirm enabling vNIC3.2 [y/n]: y
RS G8124(vnic group config)# port 5
RS G8124(vnic group config)# trunk 1
RS G8124(vnic group config)# failover
RS G8124(vnic group config)# enable
RS G8124(vnic group config)# exit