RMON Group 1—Statistics
The switch supports collection of Ethernet statistics as outlined in the RMON statistics MIB, in
reference to etherStatsTable. You can configure RMON statistics on a per-port basis.
RMON statistics are sampled every second, and new data overwrites any old data on a given port.
Note – RMON port statistics must be enabled for the port before you can view RMON statistics.
Example Configuration
1. Enable RMON on a port.
2. View RMON statistics for the port.
RS G8124(config)# interface port 1
RS G8124(config-if)# rmon
RS G8124(config-if)# show interface port 1 rmon-counters
------------------------------------------------------------------
RMON statistics for port 3:
etherStatsDropEvents: NA
etherStatsOctets: 7305626
etherStatsPkts: 48686
etherStatsBroadcastPkts: 4380
etherStatsMulticastPkts: 6612
etherStatsCRCAlignErrors: 22
etherStatsUndersizePkts: 0
etherStatsOversizePkts: 0
etherStatsFragments: 2
etherStatsJabbers: 0
etherStatsCollisions: 0
etherStatsPkts64Octets: 27445
etherStatsPkts65to127Octets: 12253
etherStatsPkts128to255Octets: 1046
etherStatsPkts256to511Octets: 619
etherStatsPkts512to1023Octets: 7283
etherStatsPkts1024to1518Octets: 38