Using the Switch Data Ports
You also can configure in-band management through any of the switch data ports. To allow in-band
management, use the following procedure:
1. Log on to the switch.
2. Enter IP interface mode.
Note – Interface 125 through 128 are reserved for out-of-band management interfaces (see “Using
the Switch Management Ports” on page 27).
3. Configure the management IP interface/mask.
Using IPv4:
Using IPv6:
4. Configure the VLAN, and enable the interface.
5. Configure the default gateway.
If using IPv4:
If using IPv6:
RS G8124> enable
RS G8124# configure terminal
RS G8124(config)# interface ip <IP interface number>
RS G8124(config-ip-if)# ip address <management interface IPv4 address>
RS G8124(config-ip-if)# ip netmask <IPv4 subnet mask>
RS G8124(config-ip-if)# ipv6 address <management interface IPv6 address>
RS G8124(config-ip-if)# ipv6 prefixlen <IPv6 prefix length>
RS G8124(config-ip-if)# vlan 1
RS G8124(config-ip-if)# enable
RS G8124(config-ip-if)# exit
RS G8124(config)# ip gateway <gateway number> address <IPv4 address>
RS G8124(config)# ip gateway <gateway number> enable
RS G8124(config)# ip gateway6 <gateway number> address <IPv6 address>
RS G8124(config)# ip gateway6 <gateway number> enable