Cabletron Systems 2000 Switch User Manual


 
FDDI Statistics 6-13
FDDI Applications
KBytes/sec
The number of kilobytes/second (averaged over the speciÞed poll interval)
transmitted by the indicated SMT.
Peak KBytes/sec
The peak number of kilobytes/second transmitted by the indicated SMT, as
detected over all polling intervals since monitoring began (i.e., since the FDDI
Statistics window was Þrst opened).
%Util
The percentage of utilization of available bandwidth by the indicated SMT over
the current poll interval; the percentage is calculated by dividing the actual
number of transmitted bytes/sec into the maximum number of bytes/sec that
could be transmitted (125,000,000 bytes/sec potential on a 100 Megabit/second
ring).
Setting the FDDI Statistics Poll Rate
To set the FDDI Statistics poll rate:
1. Click on the clock symbol ( ) next to the Poll Rate (sec) text box. The New
Timer Interval text box, Figure 6-7, will appear.
Figure 6-7. New Timer Interval Text Box
2. Using the mouse, click to highlight the hour field in the New Timer Interval text
box.
3. Using the arrow keys to the right of the text box, scroll to change the hour, as
desired. Notice that the time is given in a 24-hour hh:mm:ss format.
4. Using steps 2 and 3, continue to change the minutes and seconds fields, as
desired.
5. Click on OK when you are finished entering new information. The new Poll
Rate you have set is now entered.
The FDDI Statistics window will refresh, and the new time interval will take effect
immediately.