The SmartSwitch 2000 Chassis View
2-44 Managing the Hub
2. Click on Com Port Configuration, and then select Port 1, and release. The
Com Port Configuration window, Figure 2-17, will appear.
Figure 2-17. The Com Port ConÞguration Window
You can use the Com Port ConÞguration window to set the following operating
parameters:
Com Port Admin
Use this Þeld to administratively enable or disable the COM port.
Com Port Function
Use this Þeld to select the function for which you wish to use the COM port:
LM Local Management: select this option if you wish to connect a
terminal to the selected COM port from which to run Local
Management.
UPS Select this option if you wish to connect an uninterruptable
power supply (UPS) to the selected COM Port. Note that if you
select this option, an additional option Ñ UPS Ñ will appear on
the Device menu; use the resulting window to conÞgure speciÞc
UPS settings.
SLIP Select this option to use the selected COM port as a SLIP
connection for out-of-band SNMP management via direct
connection to a serial port on your network management
workstation. Note that when you conÞgure the port as a SLIP
connection, you must select the desired baud rate in the Speed
Selection Þeld described below.
PPP Select this option to use the selected COM port as a PPP
connection for out-of-band SNMP management via direct
connection to a serial port on your network management