EMC Host Connectivity with QLogic FC and iSCSI HBAs and FCoE CNAs for the Linux Environment
Configuring a Boot Device on an EMC Storage Array
Configuring a Symmetrix boot device for FC or FCoE
This section describes how to install an EMC-qualified version of
Linux onto an EMC Symmetrix storage array connected to an
Intel-based x86 and x86_64 class systems and AMD Opteron-based
x86_64 class systems.
Preparing the Symmetrix storage array
To prepare the Symmetrix storage array,
It is recommended that Volume Logix be enabled on the
Symmetrix storage array for LUN masking purposes.
During the installation procedure, only one LUN should be
allocated to the host, so that the boot LUN may be identified
easily. After the OS installation, additional LUNs may be
allocated.
Create a zone that includes the WWPN of the adapter to be used
and one FA port. Add the newly-created zone to the zone
configuration in the fabric and enable the zone configuration.
Preparing the host
To prepare the host,
Create a zone that includes the WWPN of the adapter to be used
and one FA port. Add the newly-created zone to the zone
configuration in the fabric and enable the zone configuration.
The PCI Fibre Channel adapter must be the lowest-numbered PCI
slot in the server. For example, if there are three adapters in the
system in slots 2, 4, and 5, connect the cable to the adapter in slot.
Do not connect cables to other adapters until the installation is
complete and the host rebooted.
SCSI hard disks are allowed in SAN boot configurations.
However, the BIOS for the disk's SCSI adapters must be disabled.
Any SCSI disks attached to the host should be disconnected
during the operating system installation.
For servers with SCSI CD-ROM drives, ensure that the BIOS is
enabled on the SCSI channel that includes the CD-ROM. Disable
the BIOS on any other integrated SCSI channels.