CONFIDENTIAL
Paper roll Miscellaneous commands GS g 0
Ver. 10.01 p. 473
GS g 0
SETTING COMMAND
[Name] Initialize maintenance counter
[Format] ASCII GS g 0
m
nL
nH
Hex 1D 67 30
00
nL
nH
Decimal 29 103 48
0
nL
nH
[Printers not featuring this command] TM-T88III, TM-L60II, TM-U230, TM-U220, TM-U210, TM-U300A/B
[Range]
m
= 0
TM-J2100: 30 ≤ (
nL
+
nH
× 256) ≤ 34,(
nL
+
nH
× 256) = 50, 70
TM-J2000: (
nL
+
nH
× 256) = 30, 31, 33, 34, 50, 70
TM-T90, TM-L90, TM-P60: (
nL
+
nH
× 256) = 20, 21, 50, 70
[Description] Sets the resettable maintenance counter specified by (
nL
+
nH
× 256) to 0.
[Notes]
■ In standard mode, this command is effective only when processed in the beginning of a line.
■ Unsupported counter numbers cannot be specified.
■ Do not use this command while a macro is being defined, because the command cannot be included in the
macro.
(
nL
+
nH
× 256) Counter
10 ~ 19 Serial impact head
20 ~ 29 Thermal head
30 ~ 39 Ink jet head
40 ~ 49 Shuttle head
50 ~ 59 Devices that conform to the normal specification
60 ~ 69 Optional devices
70 ~ 79 Time
Miscellaneous commands