Epson TM-U210 Printer User Manual


 
CONFIDENTIAL
Paper roll Customize commands GS ( C
Ver. 10.01 p. 566
GS ( C pL pH m fn b <Function 4>
[Name] Transmit the remaining capacity of the NV user memory
[Format] ASCII GS ( C
pL pH mfnb
Hex 1D 28 43
03 00 00 fn 00
Decimal 294067
3 00fn0
[Range] (
pL
+
pH
× 256) = 3 (
pL
= 3,
pH
= 0)
m
= 0
fn
= 4, 52
b
= 0
[Description] Transmits the number of bytes of remaining memory (unused area) in the NV user memory.
ESC/POS Handshaking Protocol is not required for this function.
[Notes]
With this function, the printer sends the “Header to NUL” data shown below:
(*1)
The available capacity indicates the number of bytes not being used.
The decimal value for the available capacity is converted to ASCII character data and sent from the most
significant digit.
Example: When 120 bytes is available (not being used), the number 120 is expressed with
3 bytes of data (Hexadecimal: 31H, 32H, and 30H / decimal numbers = 49, 50, and 48).
See previous [Notes for transmission process] for process sending data group.
Send data Hex Decimal Data quantity
Header 37H 55 1 byte
Identifier 29H 41 1 byte
Available Capacity
(*1)
30H 39H 48 57 1 8 bytes
NUL 00H 0 1 byte