CONFIDENTIAL
Paper roll Customize commands GS ( E
Ver. 10.01 p. 581
Setting of [Msw 8-3] is supported differently, depending on the firmware version.
Setting of [Msw 8-5] affects the performing of command GS k.
Setting the memory switch can be changed by “Memory switch setting mode” by the panel switch operation
when the power supply is turned on as shown below.
TM-L90
Receive buffer capacity [Msw 1-2]: Large (when
b
= 48) = 4 KB; small (when
b
= 49) = 45 bytes
“DM-D (customer display) is connected or not” [Msw 1-6] function is not supported.
“Selecting character code system for the simplified Chinese model” [Msw 2-3] is not supported.
• When
a
= 8, memory switch 8 is set as follows:
8-5 48 Spacing of both sides for bar code: not inserted
49 Spacing of both sides for bar code: inserts a space
8-6 to 8-7 50 Reserved
8-8 48 Roll paper cover open during printing: automatic recoverable error
49 Roll paper cover open during printing: recoverable error
Printer model The memory switch can be changed by “Memory switch setting mode”
Other than Japanese model [Msw 1-1] ~ [Msw 1-4], [Msw 1-7], [Msw 1-8], [Msw 2-2], [Msw 8-7]
Japanese model [Msw 1-2] ~ [Msw 1-4], [Msw 1-7], [Msw 1-8], [Msw 2-2]
Msw Setting value (
b
) Function
8-1 50 Reserved
8-2 48 Recovery from paper layout error: DLE ENQ execution or opening/closing the
cover
49 Recovery from paper layout error: DLE ENQ execution
8-3 48 PAPER LED is on when a paper near end is detected
49 PAPER LED is off when a paper near end is detected
8-4 48 Sets the maximum length of automatic paper measurement to 160 mm
49 Sets the maximum length of automatic paper measurement to 300 mm