Fostex PD606 Network Card User Manual


 
176
Location Recorder Model PD606
Chapter 8: MENU mode/BATTERY SETUP menu
<Battery setting examples>
<Example 1>: The [DC-IN] power is normally used while a battery set to battery mount 1 is standby
for backup.
Power priority: DC-IN, Active battery: BATT1
BATT1 is on
standby.
DC-IN is active.
DC-IN is
disconnected.
BATT1 is active.
BATT1 is on
standby.
DC-IN is restored.
[BATT1] indicator is unlit.
[BATT1] indicator is lit.
[BATT1] indicator is unlit.
Status information
display
Status information
display
Status information
display
<Example 2>: The battery mounted on battery mount 1 is normally used while the [DC-IN] is on
standby for backup.
Power priority: BATT., Active battery: BATT1
BATT1 is active.
BATT1 battery is
being replaced.
BATT1 battery
replacement
finished.
DC-IN is on standby.
Status information
display
Status information
display
Status information
display
DC-IN is active.
DC-IN is on standby.
[BATT1] indicator is lit.
[BATT1] indicator is unlit.
[BATT1] indicator is lit.
Pop up window
Pop up window
Pop up window
Pop up window