183
Location Recorder Model PD606
Chapter 8: MENU mode/TC SETUP menu
Using the "Gen mode" menu item, you can select the generator mode of the internal TC genera-
tor. You can also select the generator mode using the quick setup mode.
Rec Run
24H Run
Ext Run
Free Run
When recording, the unit records the incoming external time code.
If the unit does not receive external time code, the unit always records the Default LTC
start time at the beginning of the file.
When recording, the unit records time code which continues from the last time code value
of the previous audio file. If you change to a new disk which does not have any audio file
and make recording, the unit records time code which continues from the last time code
value of the most recent audio file on the disk previously set.
When recording, the unit records time code based on the current internal RTC (real-time
clock) time.
When recording, the unit records time code generated by the internal generator which runs
freely.
Generator mode selection [Gen mode]
1) When the unit is stopped, press the [SHIFT] key to light the [SHIFT] indicator, followed by the
[TIME/
TC SET] key.
The display now shows the TC SETUP menu screen.
2) Use the [MENU] dial to select the “Gen mode” menu item, and press the [ENTER/YES] key.
The current setting starts flashing and you can now select the desired option.
3) Use the [MENU] dial to select the desired option, and press the [ENTER/YES] key to confirm
your setting.
4) Press the [EXIT] key repeatedly until you exit the MENU mode.
Flashing
You can select from among “Rec Run”, “Ext Run”, “Free Run” and “24H Run” (the default is “Rec Run”).
Options