Gateway 9415 Server User Manual


 
144
www.gateway.com
Environmental specifications
The following specifications identify maximum environmental conditions. At no time
should the server run under conditions which violate these specifications.
Variable Requirements
Temperature Nonoperating: -40° to 158°F (-40° to 70°C)
Operating: 50° to 95°F (10° to 35°C) with a maximum rate of change
not to exceed 10° per hour
Humidity Nonoperating: 90% relative (noncondensing) at 95° F (35° C)
Acoustic noise Sound Pressure: 55 dBA (Rackmount) in an idle state at typical office
ambient temperature. (73.4 +/- ° F) Sound Power: 7.0 BA in an idle
state at typical office ambient temperature. (73.4 +/- 3.6° F)
Shock Operating - 2.0 g, 11 mSec, 1/2 sine
Unpackaged - Trapezoidal, 25 g, velocity change 136 inches/sec
( 40 lbs to > 80 lbs).
Packaged - Non-palletized free fall in height 24 inches ( 40 lbs to
> 80 lbs)
Vibration 5 Hz to 500 Hz, 2.20 g RMS random
Electrostatic
discharge (ESD)
Tested to +/-15 kV, except I/O port +/- 8kV per Intel Environmental
test specification
System cooling
requirement in
BTU/Hr
2322 BTU/hour (Based on 520W maximum power, 78% power
subsystem efficiency, and 98% power factory correction loss)
8510522.book Page 144 Wednesday, March 16, 2005 11:19 AM