HP (Hewlett-Packard) 354 Server User Manual


 
Chapter 13 Alternative Rack Mounting (4–Post)
120
Placing the HP Netserver in the Rack
Use this topic to insert the HP Netserver into the outer-rail assembly mounted in
the rack. Once the Netserver is in the rack, you can connect the cables to the rear
of the Netserver.
WARNING To prevent rack instability while mounting the HP Netserver,
ensure the rack's anti-tip foot is pulled forward out of the
bottom of the rack. Failure to do so could result in injury and
equipment damage.
To prevent the rack from rolling while you mount the HP
Netserver, ensure the leveler screws on the rack's lower four
corners are in firm contact with the floor. See Figure 13-4.
1. Lower the leveler screws on the rack's lower four corners to make firm
contact with the floor. See Figure 13-4.
2. Ensure you have extended the anti-tip foot from the rack before continuing
this procedure. See Figure 13-4.
NOTE The HP Netserver weighs 32 lbs. (14.5 kg.) fully loaded. It is
not necessary to use two people when placing the Netserver
into the rack, but it may be helpful.
3. Lift the HP Netserver by its inner-rails off the floor or pallet.
4. Move the rear of the inner-rails mounted on the Netserver just beyond the
inside edge of the outer-rail assemblies. See Figure 13-6.
The mounting inner-rails should sit just inside the outer-rails with nothing
preventing the Netserver from moving into the outer-rails.