Chapter 8 Rack Mounting the HP Netserver (4-Post)
80
Placing the HP Netserver in the Rack
Use this procedure to insert the HP Netserver into the outer-rail assemblies
mounted in the rack. Once the Netserver is in the rack, then you can connect the
cables to the rear of the Netserver.
WARNING To prevent rack instability while mounting the HP Netserver,
ensure the rack's anti-tip foot is pulled forward out of the
bottom of the rack. Failure to do so could result in injury and
equipment damage.
To prevent the rack from rolling while you mount the HP
Netserver, ensure the leveler screws on the rack's lower four
corners are in firm contact with the floor. See Figure 8-4.
1. Ensure the leveler screws on the rack's lower four corners make firm contact
with the floor. See Figure 8-6.
2. Ensure you have extended the anti-tip foot from the rack before continuing
with this procedure. See Figure 8-6.
NOTE The HP Netserver weighs 32 lbs. (14.5 kg.) fully loaded. It is
not necessary to use two people when placing the Netserver
into the rack, but it may be helpful.
3. Lift the HP Netserver by its inner rails off the floor or pallet.
4. Move the rear of the rails mounted on the Netserver just beyond the inside
edge of the outer-rail assemblies. See Figure 8-6.
The mounting rails should sit just inside the outer-rails with nothing
preventing the Netserver from moving into the outer-rails.