HP (Hewlett-Packard) BMD00022 Switch User Manual


 
Configuration Menu 115
Table 81 SSHD Configuration Menu options
Command Description
off
Disables the SSH server. This is the default for the SSH server.
cur
Displays the current SSH server configuration.
RADIUS server configuration
Command: /cfg/sys/radius
[RADIUS Server Menu]
prisrv - Set primary RADIUS server address
secsrv - Set secondary RADIUS server address
secret - Set primary RADIUS server secret
secret2 - Set secondary RADIUS server secret
port - Set RADIUS port
retries - Set RADIUS server retries
timeout - Set RADIUS server timeout
bckdoor - Enable/disable RADIUS backdoor for telnet/ssh/http/https
secbd - Enable/disable RADIUS secure backdoor for telnet/ssh/http/https
on - Turn RADIUS authentication ON
off - Turn RADIUS authentication OFF
cur - Display current RADIUS configuration
NOTE: See the HP 10Gb Ethernet BL-c Switch Application Guide for information on RADIUS.
The following table describes the RADIUS Server Configuration Menu options.
Table 82
RADIUS Server Configuration Menu options
Command Description
prisrv <IP address>
Sets the primary RADIUS server address.
secsrv <IP address>
Sets the secondary RADIUS server address.
secret <1-32 characters>
This is the shared secret between the switch and the RADIUS server(s).
secret2 <1-32 characters>
This is the secondary shared secret between the switch and the RADIUS
server(s).
port <UDP port number>
Enter the number of the User Datagram Protocol (UDP) port to be
configured, between 1500-3000. The default is 1645.
retries <1-3>
Sets the number of failed authentication requests before switching to a
different RADIUS server. The range is 1-3 requests The default is 3
requests.
timeout <1-10>
Sets the amount of time, in seconds, before a RADIUS server
authentication attempt is considered to have failed. The range is 1-10
seconds. The default is 3 seconds.
bckdoor enable|disable
Enables or disables the RADIUS back door for telnet/SSH/
HTTP/HTTPS. This command does not apply when secure backdoor
(secbd) is enabled.
secbd enable|disable
Enables or disables the RADIUS back door using secure password for
telnet/SSH/HTTP/HTTPS. This command does not apply when
backdoor (telnet) is enabled.