HP (Hewlett-Packard) BMD00022 Switch User Manual


 
Configuration Menu 120
Table 85 System SNMP Configuration Menu options
Command Description
wcomm <1-32 characters>
Configures the SNMP write community string. The write community string
controls SNMP “set” and “get” access to the switch. It can have a
maximum of 32 characters. The default write community string is private.
timeout <1-30>
Sets the timeout value for the SNMP state machine. The range is 1-30
minutes. The default value is 5 minutes.
auth disable|enable
Enables or disables the use of the system authentication trap facility. The
default setting is disabled.
linkt <port>
[disable|enable]
Enables or disables the sending of SNMP link up and link down traps. The
default setting is enabled.
ufd
Enables or disables the sending of Uplink Failure Detection traps. The
default setting is disabled.
cur
Displays the current SNMP configuration.
SNMPv3 configuration
Command: /cfg/sys/ssnmp/snmpv3
[SNMPv3 Menu]
usm - usmUser Table Menu
view - vacmViewTreeFamily Table Menu
access - vacmAccess Table Menu
group - vacmSecurityToGroup Table Menu
comm - community Table Menu
taddr - targetAddr Table Menu
tparam - targetParams Table Menu
notify - notify Table Menu
v1v2 - Enable/disable V1/V2 access
cur - Display current SNMPv3 configuration
SNMP version 3 (SNMPv3) is an extensible SNMP Framework that supplements the SNMPv2
Framework by supporting the following:
a new SNMP message format
security for messages
access control
remote configuration of SNMP parameters
For more details on the SNMPv3 architecture please see RFC2271 to RFC2275.