HP (Hewlett-Packard) RP4410 Server User Manual


 
Installing the System
Installing Additional Components
Chapter 3
72
The front control panel access door is on the bezel. Opening the control panel door provides access to the
following components:
Power button
•System LEDs
Replacing the Front Bezel
To replace the front bezel, hold the bezel in mounting position and push the bezel straight into the chassis
until it snaps into place.
Front and Top Covers
CAUTION Do not operate the server without the front and top covers in place. Operation of the server
without the front and top covers in place makes the server susceptible to electromagnetic
interference (EMI) and overheating problems that result in system failure.
Observe all electrostatic discharge (ESD) safety precautions before attempting this procedure.
Failure to follow ESD safety precautions can result in damage to the server.
NOTE When the front or top cover is removed, the chassis fan units increase to high speed to assist
cooling. When the top cover is replaced at the end of the operation, the chassis fans return to
normal speed.
Removing the Front Cover
CAUTION Power the server off before removing the front cover. All components accessible behind the front
cover are cold-swappable and require power to be off.
To remove the front cover, follow these steps:
Step 1. If rack-mounted, slide the server out from the rack until it stops. (See “Extend the Server from the
Rack” on page 64.)
Step 2. Remove the front bezel. (See “Removing the Front Bezel” on page 71.)
Step 3. Loosen the four captive thumbscrews that hold the front cover in place.