enhanced low, enhanced medium, and enhanced high.
Standard, the factory default setting, is
PostScript-compatible dithering. Enhanced dithering
reduces the banding sometimes seen in
PostScript-compatible dithering, with enhanced high
producing the least banding. The factory-default
Standard setting should not be changed if you are using
the factory-default Enhanced halftone setting.
Gamma
Correction
This option allows you to choose the amount of
gamma correction for the printer. Choices are
Gamma71 (0)
Gamma53 (1)
Gamma80 (2)
Gamma106 (3)
None (4)
The default is None. The factory-default None set-
ting should not be changed if you are using the fac-
tory-default Enhanced halftone setting. Otherwise,
the gamma setting should correspond to the printer
default halftone chosen. (For example, when the 53
lpi x 45° halftone is selected, the Gamma53 gamma
setting should be selected.)
Administration/Emulations/Lineprinter
Twelve configuration choices are available:
Font In this submenu, you can enter the name of a font (any
PostScript font on the printer) to be used for Lineprinter
jobs. The factory default is Courier. To see a list of
PostScript fonts available, print an advanced status
page from the front control panel (from the
Administration/Special Pages/Print Status submenu).
Point Sz
100ths
Sets the five-digit value used to specify the point size
of the font for the current print job. The range is from
00400 (4 points) to 25600 (256 points). The default is
00880 (8.8 points).
Character
Maps
Specifies the type of character map to be used. The
choices are ASCII and EBCDIC. The default is ASCII.