Intel SX220 Power Supply User Manual


 
Viglen SX220 User Guide 65
Server Menu
Table 22: Server Menu Features
Feature Choices Description
System Management Press <Enter> Enters Submenu.
Console Redirection Press <Enter> Enters Submenu.
Event Log Redirection Press <Enter> Enters Submenu
Service Boot Enable
Disable
If enabled, server boots directly to System
Management.
Assert NMI on PERR Disabled
Enabled
If enabled, PCI bus parity error (PERR) routes to NMI.
Assert NMI on SERR Disabled
Enabled
If enabled, PCI bus system error (SERR) routes to
NMI.
FRB-2 Policy Disable BSP
Do not Disable
BSP
Retry 3 Times
Controls the policy of the FRB-2 timeout. This option
determines when the Boot Strap Processor (BSP)
should be disabled if an FRB-2 error occurs.
BMC IRQ Disabled
IRQ 5
IRQ 11
Sets the BMC IRQ.
After Power Failure Stays Off
Last State
Power On
Determines the mode of operation if a power loss
occurs.
Temperature Sensor Disabled
Enabled
If enabled, the system will not boot if the ambient
system temperature is outside the range specified in
the Sensor Data Record (SDR).
POST Error Pause Disabled
Enabled
If enabled, the system will wait for user intervention on
critical POST errors.
Platform Event Filtering Disabled
Enabled
Enable/Disable triggers for system sensor events
inside the Baseboard Management Controller (BMC).
Server Redirection Submenu
Table 23: Server Redirection Submenu Features
Feature Choices Description
Board Part Number
N/A Information field only
Board Serial Number
N/A Information field only
System Part Number
N/A Information field only
System Serial Number
N/A Information field only
Chassis Part Number
N/A Information field only
Chassis Serial Number
N/A Information field only
BIOS Revision BMC
N/A Information field only
Revision Primary HSBP
N/A Information field only
Revision
N/A Information field only
Console Redirection Submenu
Table 24: Console Redirection Submenu Features
Feature Choices Description
Serial Console Redirection
Disabled
Enabled
If enabled, BIOS uses the specified serial port to
redirect the console to a remote ANSI terminal.
Enabling this option will disable the Quiet Boot option.
Serial Port
COM1 3F8 IRQ4
Serial port and IRQ designated for server