Viglen SX220 User Guide 72
Console go directly to the server, and the DPC Console displays the text
that you would normally see on the server console.
To use this mode, you must configure the Console Redirection option of
BIOS Setup for Re-direct mode. Enabling Console Redirection requires that
the Boot Time Diagnostics Screen be Enabled in BIOS Setup. If the
redirection window does not display information, the Console Redirection is
either incorrectly configured or disabled, the EMP is disabled in BIOS Setup,
or the server is in protected mode. For DPC to function, the server must
NOT be in graphics mode.
If the DPC console fails to connect in EMP within 10 seconds and the server
can operate in Re-direct mode, a prompt is displayed with the option to
switch to Re-direct mode.
Service Partition mode. Entered when the server reboots from the service
partition and the DPC Console has successfully connected to the server
through a modem. This mode allows running of DOS-based programs that
are stored on the service partition and transferring of files.
Running the DPC Console
For more information about setting up and running the DPC Console, see the
document named "ENUDPCUG.pdf.” This document is in the Manuals\SrvMgmt
directory on the server software kit accompanying the SCB2 server board.
Using the System Setup Utility
The System Setup Utility (SSU) is located on the SCB2 System Resource CD-ROM
shipped with the server board. The SSU provides a graphical user interface (GUI)
over an extensible framework for server configuration. For the SCB2 systems, the
SSU framework supports the following functions and capabilities:
Allows configuration of Sever Management options
Allows you to specify boot device order and system security options
Permits viewing and clearing of the system’s critical event log
Allows troubleshooting of the server when the OS is not operational
Allows you to view the system’s Sensor Data Records and Field
Replaceable Unit information