6. Touch the static-protective package that contains the new ServeRAID-BR10il SAS/SATA controller to
any unpainted surface on the outside of the server; then, grasp the controller by the top edge or upper
corners of the controller and remove it from the package.
7. Align the ServeRAID controller 1 so that the keys align correctly with the connector 2 on the system
board.
8. Insert the ServeRAID controller into the connector on the system board until it is rmly seated. The
retention bracket secures the ServeRAID controller in place when the controller is rmly seated into
the connector on the system board.
Attention: Incomplete insertion might cause damage to the server or the controller.
9. Route the signal cables from the drive backplane through the fan cage hole (between fans 1 and 2)
as shown in the following illustration.
160 Hardware Maintenance Manual