1
Riser card assembly
12
Bezel
2
DIMM air bafe
13
DVD drive ller
3
DIMM
14
Operator information panel
4
Power supply
15
Fans
5
SAS/SATA backplane (some models)
16
System board
6
SATA simple-swap back panel (some models)
17
Microprocessor
7
3.5-inch drive cage
18
Heat sink
8
3.5-inch simple-swap SATA hard disk drive (some
models)
19
Cover
9
Simple-swap SATA ller
10
Hot-swap hard disk drive ller
11
3.5-inch or 2.5-inch hot-swap hard disk drive
(depending on model)
Replaceable server components
Replaceable components are of three types:
• Self-service customer replaceable unit (CRU): Replacement of self-service CRUs is your responsibility.
If Lenovo installs a self-service CRU at your request, you will be charged for the installation.
• Optional-service customer replaceable unit: You may install an optional-service CRU yourself or
request Lenovo to install it, at no additional charge, under the type of warranty service that is designated
for your server.
• Field replaceable unit (FRU): FRUs must be installed only by trained service technicians.
For information about the terms of the warranty and getting service and assistance, see the Warranty and
Support Information document.
The following table lists the part numbers for the server components.
Table 15. Parts listing, Types 6531
Index Description
CRU part
number
(Tier 1)
CRU part
number (Tier
2)
FRU part
number
1
Riser PCIX (models CTO All Models)
49Y4675
1
Riser PCI-E LP (models CTO All Models) 46C6796
1
Riser PCI-E FH (models CTO All Models)
49Y4673
2
Air Duct (models CTO All Models) 46C6798
3
Memory module, 1GB DDR3-1333 1Rx8 LP RDIMM (models
CTO)
46U1991
3
Memory module, 1GB (1x1GB, Single Rankx8) PC3-10600
CL9 ECC DDR3 1333MHz LP UDIMM (models CTO 11U 11F
11S 11L 11D 11Y 11G 11M 11A 11J 12U 12F 12S 12L 12D
12Y 12G 12M 12A 12J)
46U2906
3
Memory module, 2GB DDR3-1333 2Rx8 LP UDIMM (models
CTO)
46U2907
176 Hardware Maintenance Manual