Lenovo 6531 Computer Hardware User Manual


 
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
See Chapter 7 “Parts listing, RS210 Types 6531, 6532, 6533, and 6534” on page 175 to determine which
components are customer replaceable units (CRU) and which components are eld replaceable units (FRU).
If an action step is preceded by “(Trained service technician only),” that step must be performed only by
a trained service technician.
Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Error code Description Action
0051003 Uncorrectable DIMM error
1. If the server failed the POST memory test, reseat
the DIMMs.
2. Remove and replace any DIMM for which the
associated error LED is lit (see “Removing a
memory module” on page 125 and “Installing a
memory module” on page 125).
3. Run the Setup utility to enable all the DIMMs.
4. Run the DSA Preboot memory test (see “Running
the diagnostic programs” on page 65
).
0051006 DIMM mismatch detected Make sure that the DIMMs match and are installed
in the correct sequence (see “Installing a memory
module” on page 125
).
0051009 No memory detected. 1. Make sure that the server contains DIMMs.
2. Reseat the DIMMs.
3. Install DIMMs in the correct sequence (see
“Installing a memory module” on page 125).
005100A No usable memory detected. 1. Make sure that the server contains DIMMs.
2. Reseat the DIMMs.
3. Install DIMMs in the correct sequence (see
“Installing a memory module” on page 125
).
4. Clear CMOS memory to re-enable all the memory
connectors (see “System-board switches and
jumpers” on page 111).
0058001 PFA threshold exceeded
1. Update the server rmware to the latest level (see
“Updating the rmware” on page 211).
2. Reseat the DIMMs and run the memory test (see
“Running the diagnostic programs” on page 65
).
3. Replace the failing DIMM, which is indicated by a
lit LED on the system board.
Chapter 4. Diagnostics 21