Configuring the PortMaster 3 11-5
Configuring ISDN PRI Settings
Configuring ISDN PRI Settings
Use the following settings to configure ISDN PRI on the PortMaster 3.
Setting the ISDN PRI Switch
The switch type information is available from your ISDN PRI service provider. To set the
switch type for ISDN connections to the PortMaster ISDN PRI ports, use the following
command—entered on one line
.
Table 11-5 explains the ISDN switch options.
Command> set isdn-switch ni-2|dms-100|4ess
|att-5ess|net5|vn2|vn3|1tr6|ntt|kdd
Setting the Framing Format
Table 11-5
ISDN Switch Options
ISDN Switch Description
ni-2 National ISDN-2 (NI-2) compliant. This is the default.
dms-100 Northern Telecom DMS-100 Custom.
4ess AT&T 4ESS.
att-5ess AT&T 5ESS.
net5 European ISDN PRI standard.
vn2 France—older switch.
vn3 France—older switch.
1tr6 Germany—older switch.
ntt Japan.