Lucent Technologies PortMaster Network Router User Manual


 
Configuration Steps for an Office-to-Office Connection
15-6 PortMaster Configuration Guide
After you configure the port as shown in Table 15-3, enter the following commands to
reset the port and save the configuration:
Command> reset s1
Command> save all
For more information about asynchronous ports, refer to Chapter 5, “Configuring an
Asynchronous Port.” For more information about configuring modems, refer to Chapter
10, “Using Modems.”
Dial-In User Settings for London
You must set up a user account on the Office Router in the London office so the
PortMaster 2 in the Paris office can dial in when traffic is queued at the main office. The
new user
paris
should be configured with the values shown in Table 15-4.
After you configure the user table as shown in Table 15-4, enter the following command
to save the configuration:
Command> save all
For more information about configuring user table settings, refer to Chapter 7,
“Configuring Dial-In Users.”
Table 15-4
User Table Values
Setting Command
Username add netuser
paris
Password set user
paris
password
anypasswd
Protocol set user
paris
protocol ppp
User IP address set user
paris
destination
192.168.1.1
Netmask set user
paris
netmask
255.255.255.0
IPX network number set user
paris
ipxnet
F2
RIP routing set user
paris
rip on
MTU set user
paris
mtu
1500
Compression set user
paris
compression on