Lucent Technologies PortMaster Network Router User Manual


 
Configuration Steps for a Frame Relay Connection
13-8 PortMaster Configuration Guide
Configuring the PortMaster in Bangkok
Configure the settings for the PortMaster in Bangkok with the values in the following
sections.
Configuring Global Settings
Configure the global settings on the PortMaster in Bangkok to the values shown in
Table 13-1.
After you configure the global settings shown in Table 13-1, enter the following
command to save the configuration:
Command> save all
For more information about global parameters, refer to Chapter 3, “Configuring Global
Settings.”
Configuring Ethernet Interface Settings
Configure the Ethernet interface settings on the PortMaster in Bangkok to the values
shown in Table 13-2.
After you configure the Ethernet interface as shown in Table 13-2, enter the following
command to save the configuration:
Command> save all
Table 13-1
Global Values
Parameter Command
Gateway set gateway
192.168.20.2
Table 13-2
Ethernet Values
Parameter Command
IP address set
ether0
address
192.168.200.1
Netmask set
ether0
netmask
255.255.255.0