Configuration Steps for Leased Line Connections
19-4 PortMaster Configuration Guide
Configuring the PortMaster Office Router in Rome
Configure the settings for the PortMaster Office Router in Rome with the values in the
following sections.
Configuring Global Settings
Configure the global settings to the values shown in Table 19-1.
After you configure the global settings shown in Table 19-1, enter the following
command to save the configuration:
Command> save all
For more information about global settings, refer to Chapter 3, “Configuring Global
Settings.”
Configuring Ethernet Interface Settings
Configure the Ethernet interface on the PortMaster Office Router in Rome to the values
shown in Table 19-2.
Table 19-1
Global Values
Setting Command
IP gateway set gateway
192.168.1.1
System name set sysname
rome
Table 19-2
Ethernet Values
Setting Command
IP address set
ether0
address
192.168.200.1
Netmask set
ether0
netmask
255.255.255.0
IPX network set
ether0
ipxnet
F1
IPX frame type set
ether0
ipxframe ethernet_802.2
Broadcast address set
ether0
broadcast high
RIP routing set
ether0
rip on