Lucent Technologies PortMaster Network Router User Manual


 
Configuration Steps for an Office-to-Office Connection
15-4 PortMaster Configuration Guide
Configuring the Office Router in London
Configure the following settings on the PortMaster PCMCIA Office Router in the
London office to enable London office users to access the main office network in Paris
on demand.
Configuring Global Settings
Configure the global settings shown in Table 15-1. The values shown in the table only
apply to this example. When you are configuring your PortMaster, use values
appropriate for your network.
After you configure the global settings shown in Table 15-1, enter the following
command to save the configuration:
Command> save all
For more information about global settings, refer to Chapter 3, “Configuring Global
Settings.”
Configuring Ethernet Interface Settings
Configure the Ethernet settings shown in Table 15-2.
Table 15-1
Global Values
Setting Command
IP gateway set gateway
192.168.1.1
System name set sysname
london
Table 15-2
Ethernet Values
Setting Command
IPX network set
ether0
ipxnet
F3
IPX frame type set
ether0
ipxframe ethernet_802.2
IP address set
ether0
address
192.168.200.1
Netmask set
ether0
netmask
255.255.255.0