Lucent Technologies PortMaster Network Router User Manual


 
Configuration Steps for a Synchronous V.25bis Connection
14-8 PortMaster Configuration Guide
Configuring Global Settings
Configure the following global settings to the values shown in Table 14-6.
After you configure the global settings shown in Table 14-6, enter the following
command to save the configuration:
Command> save all
For more information about global settings, refer to Chapter 3, “Configuring Global
Settings.”
Configuring Ethernet Interface Settings
Configure the Ethernet settings to the values shown in Table 14-7.
Table 14-6
Global Value
Setting Command
IP gateway set gateway
192.168.1.2
(This is the address of the next upstream router.)
Default routing set default on
System name set sysname
miami
Table 14-7
Ethernet Values
Setting Command
Protocol set ether0
ipx
enable
IP address set
ether0
address
192.168.1.1
Netmask set
ether0
netmask
255.255.255.0
IPX network set
ether0
ipxnet
F2
IPX frame type set
ether0
ixpframe ethernet_802.2
Broadcast address set
ether0
broadcast high
RIP routing set
ether0
rip on