Configuration Steps for Shared Device Access
18-6 PortMaster Configuration Guide
Leave all other settings at their default values.
After you configure port S2 as shown in Table 18-3, enter the following commands to
reset the port and save the configuration:
Command> reset s2
Command> save all
For more information about serial asynchronous ports, refer to Chapter 5, “Configuring
an Asynchronous Port.”
Speed 1 set
s2
speed 1
115200
Speed 2 set
s2
speed 2
115200
Speed 3 set
s2
speed 3
115200
Modem control set
s2
cd on
Hardware flow control set
s2
rts/cts on
Software flow control set
s2
xon/xoff
off
Host set
s2
host default
Security set
s2
security on
(If you turn security on, you must also configure the user
table or RADIUS.)
Login service set
s2
service_login
portmaster
Device service set
s2
service_device
portmaster
Table 18-3
Serial Port Values (S2)
(Continued)
Setting Command