Lucent Technologies PortMaster Network Router User Manual


 
Configuring an Asynchronous Port 5-21
Configuring a Port for a Dedicated Connection
To configure a port for a hardwired connection, follow this procedure:
1. Set the port for network hardwired.
Command> set S0 network hardwired
2. Set the protocol.
Command> set S0 protocol slip|ppp
3. Set the maximum transmission unit (MTU) size.
Command> set S0 MTU MTU
4. Set the destination IP address.
Command> set S0 destination Ipaddress
[Ipmask]
5. Set the IPX network number if you are using IPX.
Command> set S0 ipxnet Ipxnetwork
6. Enable RIP routing.
Command> set S0 rip on|off|broadcast|listen
7. Set compression.
Command> set S0 compression on|off|stac|vj
8. Set the PPP asynchronous map (if required).
Command> set S0 map Hex
9. Set input and output filters (if using).
Command> set S0 ifilter [Filtername]
Command> set S0 ofilter [Filtername]
Omitting the
Filtername
removes any filter previously set on the port.
10. Save the configuration.
Command> save all
11. Reset the port.
Command> reset S0