Lucent Technologies PortMaster Network Router User Manual


 
Using Synchronous V.25bis Connections 14-5
Configuration Steps for a Synchronous V.25bis Connection
For more information on Ethernet settings, refer to Chapter 4, “Configuring the
Ethernet Interface.”
Configuring Synchronous WAN Port Settings
Configure the synchronous WAN port parameters with the values shown in Table 14-3.
After you configure the synchronous WAN port as shown in Table 14-3, enter the
following commands to reset the port and save the configuration:
Command> reset w1
Command> save all
For more information about synchronous ports, refer to Chapter 6, “Configuring a
Synchronous WAN Port.”
Configuring a Dial-In User
A user account must be set up on the PortMaster router in Boston so the PortMaster in
Miami can dial in when traffic is queued. The new user
miami
should be configured on
the PortMaster router in Boston with the values shown in Table 14-4.
Table 14-3
Synchronous WAN Port Values
Setting Command
Port type set
w1
network twoway
Modem control set
w1
cd on
Dial group set
w1
group
1
Table 14-4
User Table Values
Setting Command
Username add netuser
miami
Password set user
miami
password
anypasswd
Protocol set user
miami
protocol ppp
User IP address set user
miami
destination
192.168.1.1
Netmask set user
miami
netmask
255.255.255.0