Lucent Technologies PortMaster Network Router User Manual


 
Using Synchronous Leased Lines 19-7
Configuration Steps for Leased Line Connections
After you configure the Ethernet interface as shown in Table 19-5, enter the following
command to save the configuration:
Command> save all
For more information on Ethernet settings, refer to Chapter 4, “Configuring the
Ethernet Interface.”
Configuring Synchronous WAN Port Parameters
Configure the synchronous WAN port with the values shown in Table 19-6. The IP
address for the port is left unconfigured, accepting the default IP address value of
0.0.0.0.
If you are not sure of the IP address on the other end of the connection, you can set the
IP destination to 255.255.255.255 and the PortMaster will attempt to learn the address.
Leave all other settings at their default values.
After you configure the port S1 as shown in Table 19-6, enter the following commands
to reset the port and save the configuration:
Command> reset s1
Command> save all
For more information about synchronous ports, refer to Chapter 6, “Configuring a
Synchronous WAN Port.”
Table 19-6
WAN Port Values
Setting Command
Port type set
s1
network hardwired
Transport protocol set
s1
protocol
ppp
IP destination set
s1
destination
192.168.200.1
Netmask set
s1
netmask
255.255.255.0
IPX network set
s1
ipxnet
F3
Modem control set
s1
cd off
RIP routing set
s1
rip on
MTU set
s1
mtu
1500