Lucent Technologies PortMaster Network Router User Manual


 
Using ISDN BRI 12-17
ISDN BRI Unnumbered IP Configuration Example
After you configure the Ethernet interface as shown in Table 12-9, enter the following
command to save the configuration:
Command> save all
For more information on Ethernet settings, refer to Chapter 4, “Configuring the
Ethernet Interface.”
Configuring ISDN Port Settings
Configure the ISDN port with the values shown in Table 12-10 for the example in this
chapter. This example assumes that the BRI used is port S1-S2 on a PortMaster ISDN
Office Router (OR-U). If your application uses ports S10 through S29 on a
PortMaster 2E, adjust these values accordingly.
All the other settings should be left at their default values.
After you configure the synchronous WAN port as shown in Table 12-10, enter the
following commands to reset the ports and save the configuration:
Command> reset s1
Command> reset s2
Command> save all
For more information about synchronous ports, refer to Chapter 6, “Configuring a
Synchronous WAN Port.”
Table 12-10
ISDN Port Values
Setting Command
Port type S1 set
s1
network
twoway
Port type S2 set
s2
network
twoway
Dial group S1 set
s1
group
2
Dial group S2 set
s2
group
2
set directory number S1 set
s1
directory number
5552222
set directory number S2 set
s2
directory number
5552223
SPID S1 set
s1
spid
700555222200
SPID S2 set
s2
spid
7005552222301