Configuration Steps for Dial-In Access
17-6 PortMaster Configuration Guide
For more information about global settings, refer to Chapter 3, “Configuring Global
Settings.”
After you configure the global settings as shown in Table 17-2, enter the following
command to save the configuration:
Command> save all
Configuring Ports
You must configure each port you are using for dial-in on the first PortMaster, plus its
attached modem.
Configuring Ethernet Port Settings
Set the Ethernet port on the first PortMaster to the values shown in Table 17-3.
After you configure the Ethernet interface as shown in Table 17-3, enter the following
command to save the configuration:
Command> save all
For more information on Ethernet settings, refer to Chapter 4, “Configuring the
Ethernet Interface.”
Configuring Serial Modem Port Settings
The serial modem ports are designated S0 through S29 on the PortMaster. Use the set
all command to set the same values for each serial port. The port values shown in
Table 17-4 can be set on all asynchronous ports on the first PortMaster. Use the modem
Table 17-3
Ethernet Values
Setting Command
IP address set
ether0
address
192.168.1.16
Netmask set
ether0
netmask
255.255.255.0
Broadcast address set
ether0
broadcast high
RIP routing set
ether0
rip on