Lucent Technologies PortMaster Network Router User Manual


 
Configuration Steps for a Synchronous V.25bis Connection
14-4 PortMaster Configuration Guide
Configuring Global Settings
Configure the global settings to the values shown in Table 14-1.
After you configure the global settings shown in Table 14-1, enter the following
command to save the configuration:
Command> save all
For more information about global settings, refer to Chapter 3, “Configuring Global
Settings.”
Configuring Ethernet Interface Settings
Configure the Ethernet interface settings to the values shown in Table 14-2.
After you configure the Ethernet interface as shown in Table 14-2, enter the following
command to save the configuration:
Command> save all
Table 14-1
Global Values
Setting Command
IP gateway set gateway
192.168.1.1
System name set sysname
boston
Table 14-2
Ethernet Values
Setting Command
IP address set
ether0
address
192.168.200.1
Netmask set
ether0
netmask
255.255.255.0
IPX network set
ether0
ipxnet
F1
IPX frame type set
ether0
ipxframe ethernet_802.2
Broadcast address set
ether0
broadcast high
RIP routing set
ether0
rip on