Lucent Technologies PortMaster Network Router User Manual


 
Using Internet Connections 16-7
Configuration Steps for an Internet Connection
For more information about asynchronous ports, refer to Chapter 5, “Configuring an
Asynchronous Port.”
Configuring a Dial-Out Location
If you are using a continuous dial-out link, a location entry on the PortMaster must be
created for the location identified as
isp1
. This entry allows the PortMaster to establish a
connection with the ISP as soon as it is booted. The new location
isp1
should be
configured with the values shown in Table 16-5, or as instructed by your ISP.
Table 16-5
Location Table Values
Setting Command
Location name add location
isp1
Type set location
isp1
manual
(Change to continuous after testing the configuration.)
Protocol set location
isp1
protocol ppp
IP destination set location
isp1
destination
192.168.5.6
Netmask set location
isp1
netmask
255.255.255.0
RIP routing set location
isp1
rip broadcast
MTU set location
isp1
mtu
1500
Compression set location
isp1
compression on
Input filter set location
isp1
ifilter
internet.in
Output filter set location
isp1
ofilter
internet.out
Idle timer set location
isp1
idle
0
High-water mark set location
isp1
high_water
0
Dial group set location
isp1
group
1
Telephone number set location
isp1
telephone
5551212
Username set location
isp1
username
office
(This value is provided by your ISP.)