Chapter 3: 7401-2xxx and 3xxx Hardware Installation 3-37
Installation Guidelines
• To prevent moisture from entering system, the front of the display
must be in close contact with the opening in the enclosure.
• Within every custom enclosure, the Electronics Box Back Cover
MUST remain installed because it helps dissipate the heat
generated by the CPU.
• Adequate ventilation must be provided in every custom enclosure.
The maximum allowable ambient temperature within any
enclosure is 45
o
C (113
o
F).
• To prevent accidental shorts, the power supply and any other
peripherals within the enclosure must be mounted securely and
within reach of the display’s connectors.
• This model comes with a motion sensor that is at the end of a
381 mm (15 in.) cable. When using the motion sensor, it must be
mounted between 25 and 76 mm (1 to 3 in.) below the bottom of the
display and centered along the width of the display. (F753 [AT&T]
includes a front enclosure in which the motion sensor is already
mounted.)
• Compliance of this device with regulatory requirements must be
verified in the end-use application.
• This device is a component which requires a suitable enclosure in
its end-use application. The end-use product in which this
component is used should be certified in accordance with UL 1950,
EN60950, IEC950 or other applicable safety standard.
Caution: NCR displays are not designed for horizontal or inverted
use. NCR displays must be mounted no more than 40
o
forward or
backward from horizontal. Failure to follow this guideline could result
in overheating.